National Gypsum Purple Book Fire Rated Assemblies in ...NATIONAL GYPSUM COMPANY FIRE-RATED ASSEMBLIES IN COMMERCIAL CONSTRUCTION 1DWLRQDO *\SVXP 3URSHUWLHV //& ... CL Series - Rated Steel Column Assemblies CL 101 1 Hour Rated Column PN - Penetrations Through Rated Wall and Floor Assemblies 07 84 13 CL 201 CL 301 CL 401Explore further

1 hour fire rated construction

3/12/2015 b. Note 3; COLUMN TO BE 1 HR FIRE RATED Page 2 Page 3 i. Each of the columns or post need to have a 1 hour rating in order to achieve a VA construction type. ii. Each column that may be subject impact will require protection (IBC 714.4). iii. Provide a detail 12TH EDITION National Gypsum Construction GuideCOPYRIGHT 2008 NATIONAL GYPSUM COMPANY National Gypsum Company Headquarters 2001 Rexford Road Charlotte, North Carolina 28211 (704) 365-7300 Internet - nationalgypsum 40 NATIONAL GYPSUM CONVENTIONAL PLASTER SYSTEMS DETAILS DESCRIPTION Suspended Metal Lath Ceilings TECHNICAL DATA SIZE AND

2 hour wall to floor system detail - vacro.es

NATIONAL GYPSUM COMPANY 2-hour Area Separation Wall. & 0183;& 32;The 2-Hour Area Separation Wall System is a 2-hour fire wall consisting of 2 in. 50.8 mm light-gauge steel H-Studs that secure two layers of 1 in. 25.4 mm shaftliner panels friction-fit between studs and a minimum 3/4 in. 19.1 mm air space on each side. 590KB Get Price. A variety of good options are available.Gypsum board enclosures are relatively cost-effective when compared with other fire resistant products. Gypsum board walls and ceilings are commonly used in building projects for interior finishes; thus, upgrad-ing to a fire-resistive gypsum assembly achieves two goals simultaneouslyinte-rior finish and fire protection. AG Design Library Resources American GypsumWelcome to American Gypsum 's Design Library, a robust tool to help you quickly find fire and sound rated assembly information First, select the hourly rating needed; Second, choose the type of design you are seeking (example Walls/Partitions

All Things Gypsum Steel Column Fire-Resistance

All Things Gypsum Steel Column Fire-Resistance. A column is a vertical building element that provides structural support by carrying a load in compression. Columns , one of the oldest designed structural elements, were used by the Greeks and Romans to construct massive temples and bridges. A column is a vertical building element that provides Rated Steel Column Assemblies Welcome National Gypsum Assemblies Archive - Georgia-Pacific Building ProductsHourly Rating 3-hour. Fire Test Reference UL X528, cUL X528, GA CM 3116. Column . Three layers of 5/8 (16.9 mm) ToughRock&Fireguard C&or 5/8 (16.9 mm) DensArmor Plus&Fireguard C&gypsum panels, screw-attached to 1-5/8 (41.3 mm) steel studs located at each corner of W10 x 49 (metric W250 x 73) column . BCD201 Fire Design Methodologies for Code AcceptanceASTM E-119 Truss Assembly Typical 1 hour rated assembly 3/4" plywood parallel chord truss steel furring channel 5/8" proprietary type X wallboard The above figure is a typical 1-hr E119 truss assembly (UL528). It uses 5/8" type C gypsum board on furring channels (note the channels are doubled at board edges). This is on

CE Center - Concrete-Filled Hollow Structural Sections Rated Steel Column Assemblies Welcome National Gypsum

Minimum column sizes and fire ratings for both gypsum board and SFRM have been calculated for different assemblies , tested, and published in table form in the American Institute of Steel Construction (AISC) Design Guide 19 Table VI.3 for gypsum board column designs. We dont have to go through and do an equation every time. CE Center - Designing For Fire Resistance With Gypsum Rated Steel Column Assemblies Welcome National GypsumASTM Standard E119 provides the ratings for walls and partitions, floor-ceiling and roof-ceiling assemblies , beams and columns . From this nearly century-old test standard, other test standards have been developed to evaluate the level of performance of through-penetration fire stop, joint and curtain-wall systems as they relate to the desired Rated Steel Column Assemblies Welcome National Gypsum Elevator Metal StudsI-Stud Shaftwall System - SCAFCO Steel Stud Company Discover The Best Education scafco Education Details The I-Stud is compatible with the gypsum Shaftliner boards of most major companies and is contractor preferred.Shaftwall is used to enclose elevator shafts, stairwalls, air-return shafts, mechanical shafts, horizontal membranes and other non-protected

Encased With Gypsum Lath and - NIST

UNITEDSTATESDEPARTMENTOFCOMMERCESinclairWeeks, Secreta, NATIONALBUREAUOFSTANDARDSA.V.Astin,Diriclor FireTestsofSteelColumns EncasedWithGypsumLathandPlaster Rated Steel Column Assemblies Welcome National Gypsum Fire Rated Gypsum - CertainTeedType X fire rated gypsum drywall that is 5/8 -inch (15.9mm) thick and installed on each side of nominal 2-inch x 4-inch (38x89mm) wood studs spaced 16-inch (400mm) o.c. or 3-5/8 inch (610 mm) steel studs spaced 24 o.c. has a minimum fire rating for the assembly of 1 hour, which is a typical requirement for many building codes.. Type C fire rated drywall (sometimes referred to Fire proofing steel - Structural engineering general Rated Steel Column Assemblies Welcome National GypsumExample, if you cannot find a UL rating for 2 layers of gypsum and intumescent paint over steel HSS column then this assembly would have a fire rating of 0. Perally, I would wait until the architect is available to ensure that

Fire-Resistive Floor-Ceiling Assemblies Fire Engineering

Walls rated for fire resistance can be built of poured-in-place concrete, precast concrete wall panels, concrete mary units, brick, layers of gypsum drywall board supported by steel studs, and Rated Steel Column Assemblies Welcome National Gypsum GA-605-2018 PROPRIETARY GYPSUM PANEL PRODUCTS Georgia-Pacific Gypsum LLC 4 National Gypsum Company 5 Rated Steel Column Assemblies Welcome National Gypsum Type LWX 5/8 ToughRock&Lite-Weight Fire-Rated Gypsum Type TP-6 1 ToughRock&Shaftliner Type DGG 5/8 DensGlass&Fireguard&Sheathing 5/8 DensElement&Barrier System Type DD 5/8 DensDeck&Fireguard&Roof Board Rated Steel Column Assemblies Welcome National Gypsum GFRG Panel GFRG Panel House GFRG Panel Price GFRG Rated Steel Column Assemblies Welcome National GypsumGFRG panel is available in the standard size of 12.0 m length, 3.0 m height and 124 mm thick, with modular cavities. These cellular cavities are formed between outer skins (flanges), 15 mm thick and interconnecting ribs, 20 mm thick, at 250 mm spacing.

GOLD BOND BRAND GYPSUM SHEATHING - Construction

Gypsum Sheathing can also be used as a sheathing for use in fire-rated exterior wall assemblies . ADVANTAGES Low material and application costs. The noncombustible gypsum core of the sheathing protects framing elements even when the siding or finish material is combustible. Gypsum Sheathings moisture-resistant core and GYPSUM BOARD ASSEMBLIES - Columbia Universitywith a G60 class zinc coating, to satisfy AISI Specifications for the Design of Cold-Formed Steel Structural Members. 2.4 Gypsum Board Comply with ASTM C840 as amended by the following a. Wallboard ASTM C36; Type X for fire-rated assemblies ; 5/8-inch thick. b. Backing Board ASTM C442; Type X for fire-rated assemblies ; 5/8-inch thick. Gypsum Association A not-for-profit trade association Rated Steel Column Assemblies Welcome National GypsumA not-for-profit trade association founded in 1930, promoting the use of gypsum while advancing the development, growth, and general welfare of the gypsum industry in the United States and Canada on behalf of its member companies

Gypsum Association Releases Revised Technical Documents Rated Steel Column Assemblies Welcome National Gypsum

The Gypsum Association (GA) is pleased to announce that two technical documents, GA-236, Joint Treatment Under Extreme Weather Conditions and GA-253, Application of Gypsum Sheathing, have been revised and updated. Gypsum Board Types & Gypsum Products Georgia-Pacific Since 1965, Georgia-Pacific Gypsum has been committed to developing the highest quality gypsum building products in the industry. Our versatile ToughRock &gypsum boards are ideal for a wide range of commercial and residential interior applications, and our Dens &family of high-performance fiberglass mat-faced gypsum products offer exceptional strength and How big is gypsum board at non rated assemblies?How big is gypsum board at non rated assemblies?Gypsum Board at Non-Rated Assemblies 1/2 inch thick. Gypsum Board at Fire-Resistive Rated Assemblies 5/8 inch thick, UL labeled, and conforming to ICC ES Report for Type X or Type C.MASTER SPECIFICATION SECTION 092900 Based on CSI Rated Steel Column Assemblies Welcome National Gypsum

How to use the National Gypsum Company construction guide?How to use the National Gypsum Company construction guide?HOW TO USE THE NATIONAL GYPSUM COMPANY GYPSUM CONSTRUCTION GUIDE NATIONAL GYPSUM PRODUCTS FOR ALL YOUR BUILDING NEEDS Your National Gypsum Company Gypsum Construction Guide has been carefully developed to provide you with a comprehensive guide to the entire range of National Gypsum products.12TH EDITION National Gypsum Construction Guide MASTER SPECIFICATION SECTION 092900 Based on CSI Rated Steel Column Assemblies Welcome National Gypsum

A. Gypsum Board Products Conform to general provisions of ASTM C1396. 1. Ends square cut and edges tapered. 2. Gypsum Board at Non-Rated Assemblies 1/2 inch thick. 3. Gypsum Board at Fire-Resistive Rated Assemblies 5/8 inch thick, UL labeled, and conforming to ICC ES Report for Type X or Type C. MECHANICAL PROPERTIES OF GYPSUM BOARD AT partitions consisted of steel stud and gypsum board assemblies where the gypsum board became detached during the destruction. Typically construction of gypsum board partitions and ceiling are prescribed by the building code or are specified by the architect to achieve a fire rating for a given construction type.

National Gypsum Product Reference Guide

Gypsum Board used in construction of high rated STC assemblies . Fire-Shield Shaftliner 1" (25.4 mm) thick, 2' (610 mm) wide, for solid C 1396 SS-L-30D Type IV (Includes XP) partitions, shaft walls and Area Separation Walls; Type X Grade X National Gypsum Purple Book Fire Rated Assemblies in Rated Steel Column Assemblies Welcome National GypsumNATIONAL GYPSUM COMPANY. FIRE-RATED ASSEMBLIES IN COMMERCIAL CONSTRUCTION These gypsum wallboard system details are intended solely as technical support incident to the sale and use of National Gypsum Company products. They may be used as a reference by architects, engineers, other design professionals, contractors, building code PLASTIC-REINFORCED GYPSUM BOARD MAY CREATE I accessed the suggested Web site and got data on National Gypsum s Hi-Impact brand gypsum wallboard. Rated Steel Column Assemblies Welcome National Gypsum The wallboard assembly received a one-hour rating in the ASTM E 119 test developed in Rated Steel Column Assemblies Welcome National Gypsum

Rock Island Armory Auction Catalog Daily Catalog

DCA3 FireResistanceRated WoodFrame Wall and Floor . 9 hours ago Awc View All . Fire-Resistance-Rated Wood-Frame Wall and Floor/Ceiling Assemblies Building Code Requirements For occupancies such as stores, apartments, offices, and other commercial and industrial uses, building codes commonly require floor/ceiling and wall assem-blies to be fire-resistance rated Section 09 29 00 Gypsum Board - WBDG WBDG06-01-14 GYPSUM BOARD 09 29 00 - 4 B. ASTM C954, for steel studs thicker than 0.04 mm (0.33 inch). C. For fire rated construction, type and size same as used in fire rating Square Type SS Fire Proof Column - Dean Lally LLC Rated Steel Column Assemblies Welcome National GypsumFireTrol Fire Proof Columns (Square Type SS) UL RATED FIREPROOFED COLUMNS . OD of. Tubing. X106 - 2 Hour. X104 - 3 Hour. X101 - 4 Hour. Shell Size. Wt.

Standards Gypsum Association

Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. The Gypsum Association participates by lending engineering and expertise to 11 of ASTMs committees, including Committee C11 on Gypsum and Related Building Materials and Rated Steel Column Assemblies Welcome National Gypsum Structural Steel Columns UpCodesStructural steel column , either wide flange or tubular shapes. Type X gypsum board or gypsum panel products in accordance with ASTM C1177, C1178, C1278, C1396 or C1658. The total thickness of gypsum board or gypsum panel products calculated as h in Section 722.5.1.2 shall be applied vertically to an individual column using one of the following methods:. As a single UL Wall Assemblies, Fire Rated Wall Designs USGWall Assemblies . USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies .

ULC Standards UL Canada

ULC Standards develops and publishes standards and specifications for products having a bearing on fire, life safety and security, crime prevention, energy efficiency, environmental safety, security of assets and facilities, live working and workplace safety and other areas. ULC Standards is accredited by the Standards Council of Canada as a Rated Steel Column Assemblies Welcome National Gypsum USG Fire Resistant Assemblies Head of Wall Details2 hr head of wall adjacent to beam 1 steel beam with fire proofing cut drywall short of structural deck by 5 8" scale 3" = 1' - 0" 2 hr head of wall ul hw-d-0626 12 5/8" [16] max z-clips structural slab steel beam with fireproofing reference structural drawings for beam size and fireproofing thickness 6" [150] max underside of structural slab Rated Steel Column Assemblies Welcome National Gypsum USG Fire-Resistant Assemblies Catalog (English) - SA100E Structural 53-56 Column , beam , through-penetration walls and floors, and joists. Basic methods of Fireproofing protecting columns and beams with gypsum base and veneer finishes, mineral fireproofing, and gypsum drywall. F Exterior Walls 57-59 Steel -framed, including loadbearing and non-loadbearing; and wood-framed, including loadbearing.

Ul 2 Hour Rated Fire Resistive Alarm Cables Specifications

Georgia-Pacific Gypsum Searchable Assemblies Library CL 201-2 Hour Rated Column . UL Design- X528. Download . PDF DWG Rated Steel Column Assemblies - Welcome National Gypsum The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels. Ul 2 Hour Rated Fire Resistive Alarm Cables SpecificationsGeorgia-Pacific Gypsum Searchable Assemblies Library CL 201-2 Hour Rated Column . UL Design- X528. Download . PDF DWG Rated Steel Column Assemblies - Welcome National Gypsum The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels. Fire-rated assemblies are tested and certified in Rated Steel Column Assemblies Welcome National Gypsum Ul 2 Hour Rated Fire Resistive Alarm Cables SpecificationsRated Fire Resistive Alarm Cables Specifications 2605 is the first of its kind to feature a 2 hour UL fire rating up to 1850°F / 1010°C and an all-steel exterior construction. This safe can be fully submerged under 50mm water for 8 hours. Honeywell 2 Hour Fireproof 8 Hour Waterproof Fire Safe Rated Steel Column Assemblies Welcome National Gypsum UL 2-Hour Class 350 Fire Rating . Product is Rated Steel Column Assemblies Welcome National Gypsum

Ul 2 Hour Rated Fire Resistive Alarm Cables Specifications

Rated Fire Resistive Alarm Cables SpecificationsRated Steel Column Assemblies - Welcome National Gypsum The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels. Fire-rated assemblies are tested and certified in their entirety. These designs are identified in the UL Fire Resistance Ul 2 Hour Rated Fire Resistive Alarm Cables SpecificationsUl 2 Hour Rated Fire Access our all-new collection of sound-tested, fire-rated wall assemblies . Wall Assemblies USG The Honeywell Model 2605 is the first of its kind to feature a 2 hour UL fire rating up to 1850°F / 1010°C and an all-steel exterior construction. This safe can be fully submerged under 50mm water for 8 hours. Ul x528 dwg" Keyword Found Websites Listing Keyword Rated Steel Column Assemblies Welcome National GypsumUl 2 Hour Rated Fire Resistive Alarm Cables Specifications. Urik.athas DA 14 PA 50 MOZ Rank 86. PDF DWG Rated Steel Column Assemblies - Welcome National Gypsum The ratings relate to fire tests designed to determine how quickly

What are the ASTM standards for gypsum panels?What are the ASTM standards for gypsum panels?A complete listing of the ASTM International ( ASTM) standards governing gypsum panel products is available in GA-223 Gypsum Panel Products Types, Uses, Sizes, and Standards. For the purposes of uniformity, building codes often reference consensus standards.Standards Gypsum Association White Book Steel encasements section - British Gypsum

Steel encasements (C03) This section contains steel encasement systems that provide up to 180 minutes of fire protection to structural steel columns and 120 minutes for structural steel beams and joists. Passive fire protection is a vital component of any fire safety strategy. drywall-steel framed systemsDouble-Layer Partitions Double-layer 1/2 SHEETROCK Brand Gypsum Panels, FIRECODE C Core, attached to 2-1/2 min. studs spaced 24 o.c. provide a 2-hour re rating plus sound control suitable for party walls. SHEETROCK Brand Gypsum Panels, ULTRACODE Core, provide a 4-hr. re rating with double-layer construction when UL Design U419 or U490 is specied.

research report - Steel Framing Alliance

Construction of Fire-Tested Assemblies The load-bearing wall assemblies were constructed in two ways with and without insulation in the concealed space between cold-formed sheet steel studs spaced 24 inches o.c. Tests were run on studs faced with 1/2 inch or 5/8 inch thick Type X gypsum wallboard in one, two or three layers.Explore furtherUL Wall Assemblies , Fire Rated Wall Designs USGusgFloor-Ceiling Assemblies , UL Fire Rated Floor & Ceiling Rated Steel Column Assemblies Welcome National GypsumusgUSG Fire-Resistant Assemblies Catalog (English) - SA100usgUSG Fire-Resistant Assemblies Catalog (English) - SA100usgGypsum Construction Handbook - USGusgRecommended to you based on what's popular National Gypsum&Company Gypsum Board SuppliersNational Gypsum Company is the exclusive service provider for products manufactured by Gold Bond Building Products, LLC, PermaBASE Building File Size 189KB Page Count 2 How big is a gypsum protected steel column?How big is a gypsum protected steel column?GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS For SI 1 inch = 25.4 mm, 1 foot = 305 mm. Structural steel column, either wide flange or tubular shapes. Type X gypsum board or gypsum panel products in accordance with ASTM C1177, C1178, C1278, C1396 or C1658.Structural Steel Columns UpCodes

National Gypsum Purple Book Fire Rated Assemblies in Rated Steel Column Assemblies Welcome National Gypsum

NATIONAL GYPSUM COMPANY FIRE-RATED ASSEMBLIES IN COMMERCIAL CONSTRUCTION 1DWLRQDO *\SVXP 3URSHUWLHV //& Rated Steel Column Assemblies Welcome National Gypsum CL Series - Rated Steel Column Assemblies CL 101 1 Hour Rated Column PN - Penetrations Through Rated Wall and Floor Assemblies 07 84 13 CL 201 CL 301 CL 401Submittal Sheets Contact Us About Us Resources Specifications GPS Gypsum Wallboard Column Fireproofing - BuildSiteGA CM 2452 tube steel column by 1 5/8" (43.3 mm) steel stud each corner. Face layer 5/8" (15.9 mm) Fire-Shield Wallboard. NATIONAL GYPSUM QUICK SELECTOR/GENERAL REFERENCE 21 QUICK SELECTOR GENERAL REFERENCE QUICK SELECTOR FOR FIRE AND SOUND RATED SYSTEMS COLUMN (10WF49) 5 1 hr. UL X528 One layer of 1/2"